Warehouse fire sprinkler systems in Maryland: what a new tenant, taller racks or a change in what is stored does to the system overhead.
A warehouse sprinkler system is calculated for one kind of stored goods piled to one height. Bring in a new tenant, raise the racks or swap boxed goods for plastics and the fire below can need more water than the pipe overhead was sized to deliver. The fix is lower storage, heads in the racks, a heavier system overhead or a pump.
Nothing on the ceiling looks different when that happens, which is why it gets missed in a lease and comes out late, at a plan review or a final inspection. This page is written for the tenant signing the lease, the landlord who owns the system and the general contractor pricing the fit out in the warehouse corridors we work, from Baltimore County and the BWI side of Anne Arundel to Route 1 in Howard, Prince George’s and Frederick.
Why storage decides how much water the system needs
An office fire grows across a floor. A warehouse fire grows up the face of a pallet stack, and it grows fast. So the designer of a storage building starts with two questions. What is being stored, and how high does it go?
Metal parts on wood pallets burn one way. Cartons of paper goods burn hotter. Plastics burn hotter still, and plastic totes and foam packaging count even when the item inside is harmless. Height works the same direction, since every extra tier of pallets is more fuel under the same heads.
Three changes that put a building outside its design
- A new tenant. The last one stored canned goods on the floor. The new one brings racks of consumer product in plastic packaging. The lease says warehouse both times, and the sprinkler design only covered the first.
- Taller racks.A tenant who has been in the building for years adds a beam level to use the clear height. The top of the load moves up, and it also moves closer to the heads. Howard County’s inspection checklist wants all storage at least 18 inches below the sprinkler heads, and a stack that crowds the heads blocks the spray on top of everything else.
- Different goods on the same racks. Nothing moves and nothing gets built. The product line changes, or the packaging does, and plastics take the place of boxed goods.
Is one of those three yours? Text a photo of the racks and the data plate to (240) 222-5257 and we will tell you whether the storage fits what the system was built for.
What the hydraulic data plate says
Every calculated system carries a small metal plate at the riser. Baltimore County’s inspection page says it in one line, that the hydraulic data plate must be displayed in the riser room. The plate gives the water numbers the system was designed around, meaning how much water has to land on how large an area of floor, and the flow and pressure the system needs where the water comes in to do it.
The plate is the summary. The original drawings and hydraulic calculations are the full record, with the stored goods and the storage height behind those numbers. Landlords, keep that set for the life of the building. Our guide to reading the placard on a riser walks through the same kind of plate on a house system.
What we check against it
- The plate and the drawings. What the system was calculated to deliver, and for what storage.
- The storage plan. What the tenant will store, how it is packaged, whether it sits on the floor or in racks, and the height of the top of the load.
- The heads and the pipe overhead. The make and model of the heads, their spacing, the pipe sizes and the clear height under the roof deck.
- The water supply. What the main in the street delivers today, from a flow test, and whether a pump is already on the system.
- The last inspection report. A system with open deficiencies has to get those cleared whatever the storage turns out to be. Our guide to commercial sprinkler inspections covers what that report holds.
Text the plate, the rack drawings and the address to (240) 222-5257, or call us at (240) 222-5257, and we will check the storage against the design and send back in writing which way the building falls.
The four ways to close the gap
When the storage asks for more than the system gives, there are four ways out.
| Option | What changes | Where it fits |
|---|---|---|
| Lower the storage | The top tier comes off, or the hotter goods move to a limited area | The tenant can live with less cube and wants no construction |
| Add in rack heads | Sprinkler pipe and heads go inside the racks, fed from the system overhead | Fixed racking that will stay put for the length of the lease |
| Upgrade the overhead | New heads, and often bigger pipe, across the storage area | A landlord who wants the building to suit the next tenant too |
| Add a fire pump | A pump raises the pressure the public main cannot supply | The pipe is right and the street supply is what falls short |
Each one has a catch. Lower storage only works if the warehouse staff hold the line after the inspector leaves. In rack heads move with the racks, so a new layout means new pipe. An overhead upgrade is the biggest job of the four. A pump needs a room, power and its own testing, and Montgomery County will not take one as a shortcut. Its rule is that the public supply has to be shown to be inadequate before a pump goes in, and every pump is its own permit. Pricing depends on the building, and the ranges we publish are on the cost page.
Send the storage plan to (240) 222-5257 and we will tell you which of the four fits the building and put a written quote behind it.
Montgomery County calculates new systems for the height the building offers
Montgomery has new systems calculated for the highest hazard and most demanding use the building permit or the zoning allows, and for the storage height the building makes available. In plain terms, a new warehouse there is designed for what the shell can hold and not only for what the first tenant plans to stack.
That helps the next tenant in a newer Montgomery building. An older building, or one in another county, may have been designed around its first tenant’s storage, and the drawings are the only way to know.
The permit
In rack heads, an overhead upgrade and a pump are all changes to the system, and the big counties want a permit for any of them. Montgomery requires a fire protection permit for all work that adds to or modifies a system. Anne Arundel wants one before any alteration or addition of sprinklers, whatever the size of the job. Baltimore County requires a permit before a system is altered. Prince George’s wants a permit even on a small job. The licensed sprinkler contractor on the job does the design and the calculations and pulls the permit.
A warehouse lease usually comes with new walls too, an office block or a mezzanine, and our guide to moving heads for a tenant fit out covers that side. General contractors, get the rack layout and the storage plan into the bid set early.
The use and occupancy final
A new tenant needs a use and occupancy certificate before opening, and the sprinkler system is part of that inspection. In Prince George’s the faster certificate for a new tenant with no construction starts with an annual sprinkler report that has no deficiencies. In Montgomery a certificate holds until the use of the space changes. The day of the final is a bad time to find out the design is short. Our guide to the sprinkler report for use and occupancy goes county by county.
Check the system before the lease and settle the storage plan before the racks are ordered. For the wider picture of commercial work, start at our commercial fire sprinkler systems page.
What to send us
- A photo of the hydraulic data plate at the riser.
- The address and the clear height under the roof.
- What will be stored and how it is packaged.
- The rack layout, or the planned height of the top of the load.
- The existing sprinkler drawings and the last inspection report, if the landlord has them.
Text those to (240) 222-5257 or call us at (240) 222-5257. A phone photo of the plate and a rough sketch of the racks is enough for us to start.
New tenant, taller racks or different goods?
Call or text a photo of the data plate and the storage plan. We check the storage against the design and send a written quote for whatever it takes to make the two match.
Call (240) 222-5257